Autoadjustment tab of the Preferences

The controls on this tab defines how adjacent images in the stack should be adjusted.

Adjustment:

  • Vertical position defines maximum vertical shift between two images in % of their width.
  • Horizontal position defines maximum horizontal shift between two images in % of their width.
  • Rotation defines maximum angle between two images in degrees. For microscope shots this is usually not needed.
  • Magnification defines maximum difference in size between two images in % of their width.
  • Brightness checkbox defines whether brightness of the adjacent images should be normalized.
  • Resample quality is used to preserve details during alignment process. The slower resample quality is the better.
  • Depth map feathering defines the degree of smoothing of the depth map used for method B. Higher values better better mask seams between different focused areas.

Micro Panorama:

  • Vertical position defines maximum vertical shift between two images in % of their width in Micro Panorama mode.
  • Horizontal position defines maximum horizontal shift between two images in % of their width in Micro Panorama mode.
  • Reset to Default button resets all Autoadjustment preferences to default.

Read more… about micro panorama